AIIMS TEM Facility

HI I would like to have the information about the Transmission Electron Microscope Imaging facility offered at AIIMS?
Similar Threads
Thread
CGHS Facility At AIIMS
AIIMS IVF Facility
Tem Facility in AIIMS
XPS Facility In IIT Bombay
NID Facility Ranger
Facility of CAPF
Dow BPSC Facility
SBI OD Facility
AIIMS Central facility
AIIMS BBSR Facility
IIT Delhi Sem Facility
MBA Facility Management
IIT Ropar SEM Facility
XPS Facility in IIT Kanpur
JNU Central Facility

  #2  
September 17th, 2016, 11:25 AM
Super Moderator
 
Join Date: Mar 2012
Re: AIIMS TEM Facility

The details of the Transmission Electron Microscope Imaging facility offered at AIIMS has been explained below.

Transmission Electron Microscope

1 Major parts


• Basic unit has magnifying instrument section, vacuum framework and control board.

• Power supply unit-It creates and supplies energy to different parts of the essential unit.

• Electromagnetic focal points these create heat. To chill these off, cool water (~20o C) is flowed by the water chiller inside the magnifying instrument section.

• An air compressor does open and close the valves at different focuses in the segment.

2 Microscope segment

• Illumination framework (electron firearm and condenser focal points)

• Imaging framework (target focal point, projector focal point)

• Image interpreting framework (fluorescent screen, advanced photographic unit)

Illumination framework

This framework contains the electron firearm (wellspring of electrons), and the condenser that manages the power of the pillar and guides it on to the example. The electron firearm comprises of the fiber in a Wehnelt gathering and an anode. The previous is a V-formed tungsten wire and goes about as a cathode. At the point when high voltage is connected, it gets warmed up and radiates electrons. The radiated electrons frame a cloud around the tip of fiber, and are moved down the segment because of high potential (40-120 kV) produced between the fiber and the anode. The electron shaft is centered to the example by method for condenser focal point. The power of brightening is controlled by altering the central length (focal point current) of the condenser focal point. It is likewise dictated by the measure of the opening, bigger the gap size, more electrons can go through the condenser and higher is the force of brightening.

Imaging System


The target focal point frames the underlying extended picture of the example. By changing its current, the picture of the example is engaged. The projector focal point extends the last amplified picture on the screen. By shifting the current in the projector focal point, the amplification of the anticipated picture can be changed.

Image Translating System

EM gives data as varieties of electron power in the picture. To see the data contained by the transmitted electrons they are changed over into unmistakable light. This is finished by utilizing a fluorescent screen, which when assaulted with electrons, emanate photons of obvious light, which is with eyes. Pictures are obtained through a high-determination computerized CCD camera, in conjunction with picture handling programming (e.g., iTEM of Olympus Soft Imaging System, Germany).