#1
June 20th, 2014, 03:39 PM
| |||
| |||
Indian Building Research Institute
Will you please provide the list of testing and training facilities available at Central Building Research Institute ?
|
#2
June 22nd, 2014, 10:56 AM
| |||
| |||
Re: Indian Building Research Institute
Central Building Research Institute was established in the year 1947. It is located in Roorkee-247 667, Uttarakhand . Training Facilities: Waterproofing of Buildings Rural housing and sanitation Repairs and strengthening of earthquake affected houses Low cost construction technologies for hilly regions Low Cost Building Materials & Technologies GIS CBRI Pre-cast building component technology Brick Production Technologies AutoCAD Active and Passive fire protection systems Testing Facilities Workability of lime (IS: 6932 -1973). Wet grain size analysis (hydrometer analysis) including test (IS: 2720). Volume yield of lime (IS: 6932 -1973). Unconsolidated undrained triaxial tests (Cat) (IS: 2710 Part - II). Unconsolidated free swelling test (IS: 2720) Transverse strength of hydrated lime (IS: 6932 -1973). Total water-soluble salts in bricks or soil or water sample. (IS: 3495 -1976). To evaluate the physical properties of bricks and sand samples (IS: 3486, Part I & II). To determine the water absorption of cellular concrete bricks (IS: 3590 -1966). Thermal conductivity test (IS: 3346 -1980). Testing of water samples to assess its suitability for construction/brick making application (IS:456). Testing of terrazzo tiles for water absorption transverse strength and absorption (IS: 1237 -1959). Testing of tar felt for water-proofing and damp proofing (IS: 1332 -1982). Testing of sprinklers as per (IS: 1972 -1981). Testing of soils for common building bricks/clay-fly ash bricks/light weight bricks production by manual process (IS: 2117-1975, IS:137-1993). Testing of soil suitability for clay tile production (Is: 2850 -1984). Testing of sealant (IS: 12118 Part 1987). Testing of sand/marble for sieves and silt analysis (IS: 2386). Testing of quartz sand for crushing value (IS: 2386 Part 4). Testing of pre-stressed concrete poles (IS: 2905 1989, IS: 1678 and IS: 2372-1974). Testing of pre-stressed concrete poles (IS: 2905 -1989 & IS: 1678-1978 & IS: 2332 -1974). Testing of pre-constituted wood based panels materials (IS: 2380-1977). Testing of polymeric liquid waterproofing membrane (IS: 101, IS: 5913, IS: 7290). Testing of point smoke detector (IS: 11360). Testing of plywood for general purpose IS: 303 -1987. Testing of paint & varnishes durability test (salt spray test; corrosion cabinet test, sea water resistance (IS: 101 Part 6, 1988). Testing of medium density fiber-boards (I to X) (IS: 12406 -1988). Testing of lime pozzolana mixtures (IS: 4098 -1983). Testing of heat sensitive fire detector (IS: 2175). Testing of glass fiber reinforced, tissue bitumen tar felt for water proofing & damp proof (IS: 7193). Testing of flame-proof enclosures (IS: 2148 -1981). Testing of flame arrestors (IS: 11006 -1984). Testing of fired/burnt bricks for general tolerance, compressive strength, water absorption (IS: 1017-1986). Testing of durability of stones (IS: 1126 -1976). Testing of corrugated asphaltic roofing sheet (IS: 12583 - 1988). Testing of clay roof lining tiles (IS: 1478 -1976). Testing of clay flooring tiles from a single (IS: 654 -1972). Testing of clay flooring tiles (IS: 654 -1974). Testing of clay canal lining tiles (IS: 654 -1972, IS: 1478 -1976, IS: 3387 -1975). Testing of cement concrete flooring tiles (IS: 1237 -1980). Testing of cement bonded particle-boards (ISO: 8335 -1987). Testing of bricks for compressive strength water absorption (IS: 1077 -1986). Testing of block making machine (IS: 13219 -1992). Testing of bitumen mastic flooring (IS: 1195 -1978). Testing of 3 polythene sheets for tensile, elongation and permeability (IS: 2508). Tensile tests on welded plain & deformed steel reinforcing bars, (IS: 1608 - 1972, IS: 1786 - 1985). Tensile test on reinforcing bars (IS: 1608 - 1972 IS: 1786 - 1985). Stock emission monitoring (IS: 5182). Static cone penetration test (SCPT) up to 10M depth or capacity of machine 5 ton (IS: 4968 -1976). Standard penetration test (10M depth) per borehole and at 1.5M interval (IS: 2131 - 1981). Specific gravity (IS: 2720). Sound transmission loss by reverberation chamber method (IS: 9901 - 1981). Sound insulation of ACC blocks composite wall (IS: 11050 Part - 1 1984). Sound absorption coefficient by reservation chamber method (IS: 8225 - 1976). Shrinkage, moisture movement, density and water absorption (IS: 2185-1978 Part I and II). Setting time of hydraulic lime (IS: 6932 -1984). Sensitivity and thermal response assessment of heat detector IS: 1275. Sensitivity and fire response assessment of smoke detectors (IS: 1136). Quality of drinking water, natural water and waste water (IS: 24000 -1981). Popping and pitting test of lime (IS: 6832 -1973). Point load test (four specimen) (IS: 8764 -1478). Plate load test (maximum 2.0 M depth) loading intensity 40T/M (IS: 1888 - 1971 & 1982). Pile load test (Compression, Pullout and Lateral) (IS: 2911 - 1985). Physical testing of lime (IS: 712 -1984). Physical testing of cement/hydraulics (IS: 4031). Physical test and acid resistant test for bricks/tiles. (IS: 4860 -1968). Physical properties of acid resistant mortar (IS: 483 -1988). Petrographic studies of rocks and soils (IS: 1123 -1975). Permeability test (IS: 2720). Performance test of concrete vibrators immersion type (As per IS: 2505 - 1992 or screed board type - as per IS: 25061-1985 or vibrating table - as per IS: 2414 -1963). Performance test for batch type concrete mixers (IS: 4634 -1991). Performance test batch type concrete mixer (As per IS: 4634 -1991). Operation and performance requirements of cisterns for water closets and urinals (IS: 774 - 1984) reaffirmed 1990 Moisture content (IS: 2720). Model testing of artificial sky for day lighting (Is: 240 - 1975). Mechanical grain size analysis (IS: 2720, IS: 1498). Masonry strength (IS: 1905 -1987) Load test on footing in boulder deposits (75X75 cm, 1.0x1.0M, 1.5x1.5M; maximum loading 100 tons IS: 10108 -1982). Large shear box test (Consolidated undrained) (IS: 2720). Large shear box (unconsolidated undrained) (IS: 2720). Large shear box (Consolidated-drained test) (IS: 2720). Impact test & corrugated roofing sheet (IS: 12583). Flushing tests of wash down water closet/squatting pans (IS: 2556 - 1981). Flexural strength test of concrete specimens (IS: 516 - 1959). Fire resistance evaluation of safety and security equipments(IS: 3809, -1995, ISO: 834, BS: 476 Pt. 20 & 22 IS: 3614 Part 2). Fire resistance evaluation of building elements - One hour (IS: 3809, -1995, ISO:834, BS:476 Part 20 & 22 IS:3614 Part 2). Fineness of lime (IS: 6932 -1973). Field shear test (BBT, CBT percentage fines) in-situ density (IS: 10108 -1932). Evaluation of thermal response of hest detector (HD-01) (CL 5.2 of IS: 2175-1988). Evaluation of sensitivity in fire tests (CL=4.18 G IS: 1136). Evaluation of foam compounds for producing mechanical foam (IS: 4989). Evaluation of dry chemical powder for fighting fibers in burning metals (IS: 4861 -1983). Dynamic cone penetration (DCPT) up to 10M depth or refusal (IS: 4968 - 1976). Dust & Gaseous from stack (IS: 5182). Direct shear4r test (Consolidated drained test) (IS: 2720). Direct shear test for rock sample (IS: 2720). Direct shear test (un-consolidated-undrained) (IS:12634 - 1989). Direct shear test (consolidated-undrained) (IS: 2727). Differential free swelling test (IS: 2720). Determination of weathering of natural building stones (IS: 1125 -1990). Determination of water absorption, apparent specific gravity and porosity of natural building stones (IS: 1124 -1990). Determination of un-hydrated magnesia of lime (IS: 6932 -1973). Determination of true specific gravity of natural building stones (IS: 1122 -1993). Determination of soluble salts in soils (IS: 2720). Determination of mix proportions of cement sand mortar/plaster including raw materials analysis (IS: 1199-1959). Determination of durability of natural building stones (IS: 1126 -1990). Corrosion of steel re-enforcement in cellular (aerated) concrete (IS: 6441 Part 4). Consolidation test (IS: 2720). Consolidation (constant rate of strain) test (Cat) (IS: 2720). Consolidated undrained test (triaxial) (IS: 2720 Part - 12). Consolidated drained triaxial test (IS: 2720). Concrete mix design (IS: 10262 - 1982). Compressive strength test of concrete cylinder (IS: 516 - 1959). Compressive strength test of concrete cube (IS: 516 - 1956). Compressive strength of hydraulic lime (IS: 6032 - 1973). Compressive strength of concrete blocks (5 Nos.) IS: 2185-1978 Pt. II). Compressive strength and water absorption of bricks or tiles (IS: 1077-1986). Collection of un-distributed samples up to 10 M depth (IS: 1892-1979). Collection of disturbed samples up to 10M depth (IS: 1892 - 1979). Boring (dry with auger and casing after water table) up to 10M depth (IS: 1892 - 1979). Bond test by pull out method-three specimen (As per IS: 2770 Part - I, 1967). Bond strength of lime concrete (areated) (IS: 2770 Part 1). Available lime content (IS: 1514 -1990). Atterberg limit (IS: 2720). Analysis of water for its suitability for use in cement and concrete (IS: 456). Contact: Central Building Research Institute-CBRI CBRI Colony, Roorkee, Uttarakhand Map: |
|