Re: Indian Building Research Institute

Central Building Research Institute was established in the year 1947. It is located in Roorkee-247 667, Uttarakhand .

Training Facilities:
Waterproofing of Buildings
Rural housing and sanitation
Repairs and strengthening of earthquake affected houses
Low cost construction technologies for hilly regions
Low Cost Building Materials & Technologies
GIS
CBRI Pre-cast building component technology
Brick Production Technologies
AutoCAD
Active and Passive fire protection systems

Testing Facilities
Workability of lime (IS: 6932 -1973).
Wet grain size analysis (hydrometer analysis) including test (IS: 2720).
Volume yield of lime (IS: 6932 -1973).
Unconsolidated undrained triaxial tests (Cat) (IS: 2710 Part - II).
Unconsolidated free swelling test (IS: 2720)
Transverse strength of hydrated lime (IS: 6932 -1973).
Total water-soluble salts in bricks or soil or water sample. (IS: 3495 -1976).
To evaluate the physical properties of bricks and sand samples (IS: 3486, Part I & II).
To determine the water absorption of cellular concrete bricks (IS: 3590 -1966).
Thermal conductivity test (IS: 3346 -1980).
Testing of water samples to assess its suitability for construction/brick making application (IS:456).
Testing of terrazzo tiles for water absorption transverse strength and absorption (IS: 1237 -1959).
Testing of tar felt for water-proofing and damp proofing (IS: 1332 -1982).
Testing of sprinklers as per (IS: 1972 -1981).
Testing of soils for common building bricks/clay-fly ash bricks/light weight bricks production by manual process (IS: 2117-1975, IS:137-1993).
Testing of soil suitability for clay tile production (Is: 2850 -1984).
Testing of sealant (IS: 12118 Part 1987).
Testing of sand/marble for sieves and silt analysis (IS: 2386).
Testing of quartz sand for crushing value (IS: 2386 Part 4).
Testing of pre-stressed concrete poles (IS: 2905 1989, IS: 1678 and IS: 2372-1974).
Testing of pre-stressed concrete poles (IS: 2905 -1989 & IS: 1678-1978 & IS: 2332 -1974).
Testing of pre-constituted wood based panels materials (IS: 2380-1977).
Testing of polymeric liquid waterproofing membrane (IS: 101, IS: 5913, IS: 7290).
Testing of point smoke detector (IS: 11360).
Testing of plywood for general purpose IS: 303 -1987.
Testing of paint & varnishes durability test (salt spray test; corrosion cabinet test, sea water resistance (IS: 101 Part 6, 1988).
Testing of medium density fiber-boards (I to X) (IS: 12406 -1988).
Testing of lime pozzolana mixtures (IS: 4098 -1983).
Testing of heat sensitive fire detector (IS: 2175).
Testing of glass fiber reinforced, tissue bitumen tar felt for water proofing & damp proof (IS: 7193).
Testing of flame-proof enclosures (IS: 2148 -1981).
Testing of flame arrestors (IS: 11006 -1984).
Testing of fired/burnt bricks for general tolerance, compressive strength, water absorption (IS: 1017-1986).
Testing of durability of stones (IS: 1126 -1976).
Testing of corrugated asphaltic roofing sheet (IS: 12583 - 1988).
Testing of clay roof lining tiles (IS: 1478 -1976).
Testing of clay flooring tiles from a single (IS: 654 -1972).
Testing of clay flooring tiles (IS: 654 -1974).
Testing of clay canal lining tiles (IS: 654 -1972, IS: 1478 -1976, IS: 3387 -1975).
Testing of cement concrete flooring tiles (IS: 1237 -1980).
Testing of cement bonded particle-boards (ISO: 8335 -1987).
Testing of bricks for compressive strength water absorption (IS: 1077 -1986).
Testing of block making machine (IS: 13219 -1992).
Testing of bitumen mastic flooring (IS: 1195 -1978).
Testing of 3 polythene sheets for tensile, elongation and permeability (IS: 2508).
Tensile tests on welded plain & deformed steel reinforcing bars, (IS: 1608 - 1972, IS: 1786 - 1985).
Tensile test on reinforcing bars (IS: 1608 - 1972 IS: 1786 - 1985).
Stock emission monitoring (IS: 5182).
Static cone penetration test (SCPT) up to 10M depth or capacity of machine 5 ton (IS: 4968 -1976).
Standard penetration test (10M depth) per borehole and at 1.5M interval (IS: 2131 - 1981).
Specific gravity (IS: 2720).
Sound transmission loss by reverberation chamber method (IS: 9901 - 1981).
Sound insulation of ACC blocks composite wall (IS: 11050 Part - 1 1984).
Sound absorption coefficient by reservation chamber method (IS: 8225 - 1976).
Shrinkage, moisture movement, density and water absorption (IS: 2185-1978 Part I and II).
Setting time of hydraulic lime (IS: 6932 -1984).
Sensitivity and thermal response assessment of heat detector IS: 1275.
Sensitivity and fire response assessment of smoke detectors (IS: 1136).
Quality of drinking water, natural water and waste water (IS: 24000 -1981).
Popping and pitting test of lime (IS: 6832 -1973).
Point load test (four specimen) (IS: 8764 -1478).
Plate load test (maximum 2.0 M depth) loading intensity 40T/M (IS: 1888 - 1971 & 1982).
Pile load test (Compression, Pullout and Lateral) (IS: 2911 - 1985).
Physical testing of lime (IS: 712 -1984).
Physical testing of cement/hydraulics (IS: 4031).
Physical test and acid resistant test for bricks/tiles. (IS: 4860 -1968).
Physical properties of acid resistant mortar (IS: 483 -1988).
Petrographic studies of rocks and soils (IS: 1123 -1975).
Permeability test (IS: 2720).
Performance test of concrete vibrators immersion type (As per IS: 2505 - 1992 or screed board type - as per IS: 25061-1985 or vibrating table - as per IS: 2414 -1963).
Performance test for batch type concrete mixers (IS: 4634 -1991).
Performance test batch type concrete mixer (As per IS: 4634 -1991).
Operation and performance requirements of cisterns for water closets and urinals (IS: 774 - 1984) reaffirmed 1990
Moisture content (IS: 2720).
Model testing of artificial sky for day lighting (Is: 240 - 1975).
Mechanical grain size analysis (IS: 2720, IS: 1498).
Masonry strength (IS: 1905 -1987)
Load test on footing in boulder deposits (75X75 cm, 1.0x1.0M, 1.5x1.5M; maximum loading 100 tons IS: 10108 -1982).
Large shear box test (Consolidated undrained) (IS: 2720).
Large shear box (unconsolidated undrained) (IS: 2720).
Large shear box (Consolidated-drained test) (IS: 2720).
Impact test & corrugated roofing sheet (IS: 12583).
Flushing tests of wash down water closet/squatting pans (IS: 2556 - 1981).
Flexural strength test of concrete specimens (IS: 516 - 1959).
Fire resistance evaluation of safety and security equipments(IS: 3809, -1995, ISO: 834, BS: 476 Pt. 20 & 22 IS: 3614 Part 2).
Fire resistance evaluation of building elements - One hour (IS: 3809, -1995, ISO:834, BS:476 Part 20 & 22 IS:3614 Part 2).
Fineness of lime (IS: 6932 -1973).
Field shear test (BBT, CBT percentage fines) in-situ density (IS: 10108 -1932).
Evaluation of thermal response of hest detector (HD-01) (CL 5.2 of IS: 2175-1988).
Evaluation of sensitivity in fire tests (CL=4.18 G IS: 1136).
Evaluation of foam compounds for producing mechanical foam (IS: 4989).
Evaluation of dry chemical powder for fighting fibers in burning metals (IS: 4861 -1983).
Dynamic cone penetration (DCPT) up to 10M depth or refusal (IS: 4968 - 1976).
Dust & Gaseous from stack (IS: 5182).
Direct shear4r test (Consolidated drained test) (IS: 2720).
Direct shear test for rock sample (IS: 2720).
Direct shear test (un-consolidated-undrained) (IS:12634 - 1989).
Direct shear test (consolidated-undrained) (IS: 2727).
Differential free swelling test (IS: 2720).
Determination of weathering of natural building stones (IS: 1125 -1990).
Determination of water absorption, apparent specific gravity and porosity of natural building stones (IS: 1124 -1990).
Determination of un-hydrated magnesia of lime (IS: 6932 -1973).
Determination of true specific gravity of natural building stones (IS: 1122 -1993).
Determination of soluble salts in soils (IS: 2720).
Determination of mix proportions of cement sand mortar/plaster including raw materials analysis (IS: 1199-1959).
Determination of durability of natural building stones (IS: 1126 -1990).
Corrosion of steel re-enforcement in cellular (aerated) concrete (IS: 6441 Part 4).
Consolidation test (IS: 2720).
Consolidation (constant rate of strain) test (Cat) (IS: 2720).
Consolidated undrained test (triaxial) (IS: 2720 Part - 12).
Consolidated drained triaxial test (IS: 2720).
Concrete mix design (IS: 10262 - 1982).
Compressive strength test of concrete cylinder (IS: 516 - 1959).
Compressive strength test of concrete cube (IS: 516 - 1956).
Compressive strength of hydraulic lime (IS: 6032 - 1973).
Compressive strength of concrete blocks (5 Nos.) IS: 2185-1978 Pt. II).
Compressive strength and water absorption of bricks or tiles (IS: 1077-1986).
Collection of un-distributed samples up to 10 M depth (IS: 1892-1979).
Collection of disturbed samples up to 10M depth (IS: 1892 - 1979).
Boring (dry with auger and casing after water table) up to 10M depth (IS: 1892 - 1979).
Bond test by pull out method-three specimen (As per IS: 2770 Part - I, 1967).
Bond strength of lime concrete (areated) (IS: 2770 Part 1).
Available lime content (IS: 1514 -1990).
Atterberg limit (IS: 2720).
Analysis of water for its suitability for use in cement and concrete (IS: 456).

Contact:
Central Building Research Institute-CBRI
CBRI Colony, Roorkee, Uttarakhand ‎

Map:


Quick Reply
Your Username: Click here to log in

Message:
Options



All times are GMT +5. The time now is 12:04 PM.


Powered by vBulletin® Version 3.8.11
Copyright ©2000 - 2024, vBulletin Solutions Inc.
Content Relevant URLs by vBSEO 3.6.0

1 2 3 4 5 6 7 8