#1
June 13th, 2014, 11:15 AM
| |||
| |||
Management Trainee papers of previous years of Engineers India Limited
Can you please give me the Management Trainee papers of previous years of Engineers India Limited as it is very urgent for me? As you want to get the Management Trainee papers of previous years of Engineers India Limited so here is the information of the same for you: 1. Distribution transformers are connected in configuration- a. Star/delta b. delta/star c. star/star d. delta/delta 2. In radial system, power is fed from- a. From one end b. from two ends c.centre d. none 3. What is capacitance grading- 4. What is voltage regulation- 5. Stinging chart is used for- 6. For an existing transmission line, the string efficiency is 80%. Now if for same set up, dc is supplied, what will be the string efficiency- a.80% b.more than 80% c. less than 80% d. 100% 7. skin effect depends on frequency- a.directly proportional b. inversely proportional c.square of frequency d. none 8. coefficient of reflection of an open ended line is- a. 1 b. -1 c.0 d. none 9. the power loss in an overloaded line is mainly due to- a. resistance b. capacitance d. inductance d. none 10.voltage at generation stage is usually- a.11kv b.33kv c.66kv d.220kv 11.HRC fuses provides best protection against- a. short circuits b. lightning c. sparking d. fire 12. resistance switching is used in case of- a. air blast CB b. bulk oil CB c. minimum oil CB d. all types of CB 13. compared to ac, in dc corona loss is- 14.corona effect is more prominent in weather conditions- 15.in force voltage analogy mass is analogus to- a. R b. L c. C d. current 16.phase margin of the system is used to- a. relative stability b. absolute stabilty c. time response d. frequency response 17.wattmeter measures- a. volt ampere b. volt ampere reactive c. apperent power d. true power 18.inductance is measured by- a. wein bridge b. sechiring bridge c. maxwell bridge d. hay bridge 19.form factor in ac means the ratio of- a. peak to avg. value b.peak to rms value c. rms to avg. value d. rms to peak value 20.in a single phase converter, the no. of SCR conducting during overlap a.1 b.2 c. 3 d. 4 21.in a three-phase full converter, output voltage pulsates at frequency of a. f b. 2f c. 3f d. 6f 22.in a three-phase full converter, every SCR conducts for- a.60deg. b. 120deg. C.180deg. d.90deg Contact Details: Engineers India Limited 1, Bhikaji Cama Place, E I House, Mohammadpur, RK Puram, New Delhi, Delhi 110066 011 2676 2121 India Map Location: Last edited by Neelurk; May 6th, 2020 at 04:34 PM. |
|